The Benefits of Using Veterinary Inhalation Anesthesia Machine

Author: Geym

Apr. 28, 2025

Small Animal Inhalation Anesthesia Machine for Uses

Generally, there are some risks and side effects in animal intravenous anesthetics surgery.

Link to APC Med

Large damage to animal health
● Discomfort is easy to occur when the injection is given.
● It can possibly cause severe respiratory and cardiovascular depression during induction of anesthesia.

Low efficiency
● Complicated procedures in pre-intravenous anesthetics.
● Not easy to control the administration.
● Depth and level of anaesthesia can not be effectively controlled.
● Unable to anesthetize multiple animals simultaneously.

Unsafety
● High risk to animal death
● Personnel easily bitten or scratched by laboratory animals

Limited applications
● Only used for a small range of animal surgeries, such as with myasthenia gravis.
● Unable to accurately reflect the signs of animal metabolism, such as with drug toxicity evaluation research.

Inhalation gas anesthetics can be used safely and effectively for general animal anesthesia surgeries. In this article, we introduce the main benefits of inhalation anesthesia, and overview of RWD animal inhalation anesthesia machines.

Inhalation Gas Anesthesia Benefits

Animal Welfare
● Inhalation anesthesia hardly interferes with an animal’s liver and kidney metabolism.
● Non-invasive operation and low complication risk after recovery, thus ensuring the welfare of laboratory animals.

Animal Safety
● The output concentration and depth of anesthesia can be precisely controlled.
● Oxygen is supplied along with anesthesia, ensuring oxygenation to the body, and reducing risks involved with anesthesia.
● Helps protect internal organs.
● Can easily be used to suppress stress response.

Personnel Safety
● Non-invasive anesthetic wasted gases with the help of gas evacuation apparatus and closed-circle connection design.
● No need to get in touch with injection needle and avoid the bitten and scratched by animal.
● Easy operation and set up, also could support multiple channel experiment with different experiment requirement.

Convenient
● Real-time adjustment of anesthesia status, stable and rapid recovery from anesthesia, easy to operation.
● Multiple animals can be anesthetized simultaneously, simply, and efficiently.

Wide Range of Application
● Used for rats, mice, hamsters, guinea pigs, rabbits, cats, dogs, and other animals weighing less than 100 kg (220 lb).
● Prolonged anesthesia: such as in open thoracotomy, imaging observation surgery, etc.
● Abbreviated anesthesia: such as with orbital blood collection from rats, marking animals, simple animal trauma treatment, etc.
● Overdosing of anesthesia: such as with animal euthanasia, in-depth study of anesthesia, etc.

Easy to Use
● Simple to operate and easy to learn how to use.
● Easy to set up and disassemble.

RWD Small Animal Anesthesia Machines

R500 Compact Small Animal anesthesia machine

Key message: A Standard and Easy Choice
Features:

● Small size, saving laboratory space.
● Ability to attach different components to meet diversified experimental needs; such as extended flow meter components (Different gas sources such as laughing gas, carbon dioxide, nitrogen, etc. can be attached).

R540 enhanced small animal anesthesia machine

Key message: A Classic Choice and Best-seller for the Past Ten Years
Features:
● Wall-mount design, can be easily installed and hung on the wall to make full use of laboratory space.
● Stainless steel handle, convenient to be picked up and taken on the go, moved around, or used at any time.

Are you interested in learning more about Veterinary Inhalation Anesthesia Machine? Contact us today to secure an expert consultation!

R550 Multi-output animal anesthesia machine

Key message: first choice for high-throughput anesthesia
Features:

● The unique design of the induction box and anesthesia mask can simultaneously induce and maintain anesthesia, saving experimental time and improving work efficiency.
● The air channel for each anesthesia mask is able to be controlled independently, allowing five small animals to receive a proper amount of anesthesia simultaneously, or to give anesthesia only to select animals that need it.

R520/R530 Moveable small animal anesthesia machine

Key message: the preferred choice for mobility
Features:

● Provides integrate gas supply, induction of anesthesia, recovery of waste anesthetic gases, is convenient to set up and take down, and saves space.
● Swivel casters with locks provide easy stop and go, making mobile operation and unified management convenient.

Recommended Solutions for Animal Surgery and Modeling Applications

Multi-function animal anesthesia solutions

● It can meet the anesthetic needs of 1-5 animals at the same time, and is compatible with MRI, PET, and SPECT imaging systems.
● The tube and mask can be placed and fixed arbitrarily on the desktop, and the height of the mask can be adjusted up and down.
● Provides active waste gas recovery to better protect the physical and mental health of operating personnel.

Stereotaxic animal anesthesia solutions

● Different types of locators and adapters can be exchanged to meet the needs of different stereotaxic brain surgeries.
● Provides active waste gas recovery to better protect the physical and mental health of operating personnel.

Combination of Ventilation to Anesthesia System for Small Animal
● Surgery for animals that cannot breathe on their own due to long-term application or certain diseases that cause respiratory dysfunction.
● Suitable for mice, rats, guinea pigs and other animals weighing less than 1 kg (2.2 lb).

Combination of Ventilation to Anesthesia System for Large Animal
● Suitable for use on pigs, monkeys, dogs, cats, and other large animals weighing around 100 kg (220 lb), this is a complete set of solutions for respiratory monitoring under anesthesia, bringing more security to large animals undergoing experimentation.

Some References

Inhalation Anesthesia and Use of Ventilators - Veterian Key


When general anesthesia is considered in farm animal species, factors that affect the decision between injectable and inhalation anesthesia include the type of procedure to be performed, anticipated duration of the procedure, inhalation anesthetic equipment availability, familiarity of the veterinarians with the anesthetic technique, and anesthetic costs. Injectable anesthesia has the advantages of easy drug administration and relatively low cost of specific anesthetic equipment or accessories required for delivery and monitoring. Delivery of an inhalation anesthetic requires expensive and specialized equipment and accessories to be able to deliver the anesthetic to the patient. However, accumulation of injectable anesthetics in the patient following repeated dosing or extended infusion required for completion of a procedure can result in delayed drug elimination and prolonged recovery. Because of the ease and speed in adjusting the depth of anesthesia with the currently available inhalation anesthetics (e.g. isoflurane, sevoflurane, and desflurane), inhalation anesthesia is often preferred for use in long procedures and also for patients that are considered at higher anesthetic risk as a result of preexisting systemic conditions. Isoflurane was first synthesized in and subsequently became a popular inhalation anesthetic in human patients in . It is still a very commonly utilized inhalation anesthetic in veterinary practice. Sevoflurane was synthesized in the early s. At that time, it was difficult to synthesize the drug and therefore it was expensive to manufacture. It was not until the late s that sevoflurane was introduced in Japan and was later marketed in the USA in [1]. Special preanesthetic considerations and preparations with respect to laryngeal and gastrointestinal anatomy and physiology prior to general anesthesia in farm animal species are discussed in detail in Chapter 1.


The goal of delivering surgical anesthesia with an inhalation anesthetic is to maintain a constant and optimal partial pressure of the anesthetic in the alveoli of the lungs and central nervous systems (CNS). Currently available inhalation anesthetics, isoflurane, sevoflurane, and desflurane, have low blood solubility (isoflurane 1.46, sevoflurane 0.68, desflurane 0.42) and minimal hepatic metabolism (isoflurane 0.2%, sevoflurane 3–5%, desflurane 0.02%) [2]. Blood solubility of an inhalation anesthetic is referred to as blood–gas partition coefficient, which is the ratio of the distribution of an inhalation anesthetic between the blood and the gas. The partition coefficient is the concentration ratio of an anesthetic between the solvent and gas phase, for example blood and gas, or between two tissue solvents, for example brain and blood. As an example, an inhalation anesthetic with a blood–gas partition coefficient of 10 at equilibrium (i.e. the partial pressure of that anesthetic is identical in the blood and gas phases) implies that the concentration of that anesthetic is 10 in the blood and 1 in the gas phase. An anesthetic with a lower blood solubility has a lower blood–gas partition coefficient. In other words, a smaller amount of the anesthetic is dissolved in the blood than in the gas phase when their partial pressures reach equilibrium. Therefore, the speed of achieving surgical plane of anesthesia, the rate of anesthetic depth variation, and the time until consciousness is returned and recovery is achieved are normally faster for an inhalation anesthetic with a lower blood solubility than anesthetics with higher blood solubility. In this case, the time of induction to surgical plane of anesthesia and the time to recovery of full motor function of a patient are faster with desflurane (0.42), intermediate with sevoflurane (0.69), and slower with isoflurane (1.41) [2].


Under ideal conditions, the partial pressure of an anesthetic from the alveoli (P A) to the pulmonary arterial blood (P a) and then to the brain (P br) should be close, if not equal, to the inspired anesthetic partial pressure (P I), that is, P I ≈ P A ≈ P a ≈ P br, at equilibrium. Changes in P I, alveolar ventilation, and the characteristics of an anesthetic breathing system will affect the uptake of the anesthetic from the inspired anesthetic gas flow delivered by the anesthesia machine to the alveoli. Variation of the blood–gas partition coefficient of the anesthetics, the cardiac output of the patients, and the alveoli to venous partial pressure difference affect the transfer of an inhalation anesthetic from the alveolar tissues to pulmonary arterial blood. Factors that determine how quickly the inhalation anesthetic accumulates in the brain include the brain–blood partition coefficient, the cerebral blood flow, and the cerebral arterial to venous partial pressure difference. Because the brain–blood partition coefficients for isoflurane (1.6) and sevoflurane (1.7) are very similar, there should be no significant difference in the speed of the transfer from blood to brain between these two anesthetics [1]. Therefore, increasing P I and alveolar ventilation and reducing anesthesia breathing system volume decreases the time of the partial pressure of an inhalation anesthetic to equilibrium between alveoli and pulmonary arterial blood, and therefore results in a faster induction of anesthesia for that anesthetic. Vice versa, decreasing P I and alveolar ventilation and increasing the volume of the anesthesia breathing system prolongs the time to equilibrium and results in a slower induction of anesthesia. Furthermore, anesthetics with a low blood–gas partition coefficient, patients with a low cardiac output, and small differences between alveolar and venous partial pressures tend to result in faster induction than an anesthetic with greater blood–gas partition coefficient, patients with an increased cardiac output, and larger differences between alveolar and venous partial pressures. Similarly, an anesthetic with a low brain–blood partition coefficient, patients with increased cerebral blood flow, and small differences between cerebral arterial and venous partial pressures tend to result in a faster induction than those with a greater brain–blood partition coefficient, patients with decreased cerebral blood flow, and larger differences between cerebral arterial and venous partial pressures. These tend to result in a slower induction of anesthesia [1, 3]. Return of consciousness and recovery from inhalation anesthesia is an inverse process of induction, which is a result of the elimination of the anesthetic from the CNS. Therefore, factors that affect the speed of induction, for example alveolar ventilation, cardiac output, and blood and tissue solubility, also affect the speed of recovery. In the presence of normal alveolar ventilation and cardiac output, recovery is generally faster for an anesthetic with lower blood and tissue solubility. Hence, recovery from desflurane (0.42) and sevoflurane (0.69) tends to be faster than from isoflurane (1.41).


Isoflurane and sevoflurane are the two most commonly used inhalation anesthetics in current veterinary practice (Figures 6.1 and 6.2). Both anesthetics can be used safely and effectively for general anesthesia in farm animal species. Desflurane is a newer inhalation anesthetic with a chemical structure similar to isoflurane with the exception of the substitution of a fluorine for the chlorine on the alpha‐ethyl carbon. Desflurane is unique among the conventional inhaled anesthetics. It has a vapor pressure of 681 mmHg at 20 °C, which is very close to the atmospheric pressure (760 mmHg) and a boiling point of 22.8 °C. At normal operating room temperature, desflurane can boil with a saturated vapor concentration of 87% (681 mmHg/760 mmHg), which is approximately 10 times the minimum alveolar concentration (MAC) of desflurane for humans (6.6%). Because of these unique characteristics, desflurane requires a specially designed vaporizer that is pressurized and heated to provide precise control of anesthetic output from the vaporizer and prevent over anesthetizing the patient [4]. Because of this special vaporizer requirement, desflurane has not been used as commonly as isoflurane and sevoflurane. Isoflurane and sevoflurane require a standard vaporizer calibrated specifically for each anesthetic. Compared to older inhalation anesthetics, isoflurane and sevoflurane have lower potency with MAC values of 1.29% and 2.33%, respectively [5]. The MAC value of an inhalation anesthetic is the minimum alveolar anesthetic concentration required to prevent gross purposeful movement in 50% of patients in response to obnoxious stimuli such as surgical incision. The MAC value is used as an indicator of the potency of the anesthetic. The higher the MAC value, the lower the potency of the anesthetic. From the physico‐chemical properties of the inhalation anesthetics, MAC values are inversely related to the blood solubility of the anesthetic. Therefore, an inhalation anesthetic with high potency normally has a high blood solubility but a low MAC value. On the contrary, an inhalation anesthetic with low potency generally has a low blood solubility but a high MAC value [1]. Sevoflurane is less potent than isoflurane, as reflected in the higher MAC values (2.33% vs. 1.29%), and lower blood solubility (0.69 vs. 1.41). One should always keep in mind that at 1 MAC (1 × MAC), only 50% of patients will not respond to obnoxious stimulation. In other words, the remainder of the patients may respond to an obnoxious stimulation, resulting in gross purposeful movement. In general, surgical anesthesia requires maintaining anesthetic concentration at 1.3 MAC to prevent 95% of the patients from responding to surgical stimulation. Thus, 1.3 MAC of an inhalation anesthetic is referred to as ED95 or surgical anesthesia [1, 3]. For very painful procedures, 1.5 MAC of an inhalation anesthetic concentration may be required to maintain surgical anesthesia. The MAC value is measured and determined in normal healthy patients anesthetized with that inhalation anesthetic alone with no other CNS‐depressing drugs such as tranquilizers, sedatives, analgesics, and injectable anesthetics administered at the time of measurement. The MAC values can be influenced by concurrent administration of anesthetic‐related drugs, alterations of the physiological conditions of the patient, or concurrent administration of medications for the treatment of other conditions or illness. Factors that may increase the MAC value of an inhalation anesthetic for a particular patient include hyperthermia (fever), hypernatremia, and drug‐induced increased CNS catecholamine levels. Increased age, hypothermia, hyponatremia, pregnancy, and concurrent administration of tranquilizers, sedatives, analgesics, injectable anesthetics, local anesthetics, neuromuscular blocking drugs, and drugs that decrease CNS catecholamine levels tend to decrease the MAC value. Duration of anesthesia and magnitude of individual anesthetic metabolism have no effect on the MAC value [6, 7]. Table 6.1 summarizes the blood–gas partition coefficient, metabolism, and MAC values of isoflurane, sevoflurane, and desflurane in farm animal species.


Eger [23] and Malan et al. [24] reported that the circulatory effects produced by desflurane closely resemble those produced by isoflurane. Sevoflurane‐induced circulatory effects have the characteristics of both isoflurane and halothane. In humans, isoflurane and sevoflurane produce a dose‐dependent decrease in mean arterial pressure primarily due to the decrease in systemic vascular resistance produced by these anesthetics. Heart rate tends to increase up to 1 MAC (1.29%) during isoflurane anesthesia, while heart rate does not increase until the concentration of sevoflurane anesthesia is greater than 1.5 MAC (1.5 × 2.3% = 3.5%). An abrupt increase in alveolar concentration of isoflurane from 0.55 to 1.66 MAC produces an increase in sympathetic nervous system and renin–angiotensin activities. As a result, transient increases in heart rate and mean arterial blood pressure occur, which may cause the anesthetist to misinterpret insufficient anesthetic depth and further increase the anesthetic concentration delivered to the patient [25]. The transient increase in heart rate and mean arterial pressure associated with an abrupt increase in anesthetic concentration has not been observed during sevoflurane anesthesia [26]. It is believed that the neurocirculatory excitatory effect of isoflurane is caused by stimulation of the sympathetic nervous system located in the upper airway and in the lung in response to a sudden increase in alveolar concentration of the anesthetic. This effect is more likely to occur for inhalation anesthetics with low blood solubility that is capable of causing a rapid rise in alveolar concentration by increasing the inspired concentration delivered to the patient [27]. However, prior administration of fentanyl, alfentanil, or clonidine has been shown to blunt the neurocirculatory excitatory response to abrupt increase of desflurane concentration [28, 29]. A similar suppression response may occur if these drugs are administered prior to isoflurane anesthesia. In general, isoflurane does not affect cardiac output as much as sevoflurane. Cardiac output decreases significantly at 1 and 1.5 MAC of sevoflurane but returns to near‐awake values at 2 MAC [30]. It is believed that isoflurane may possess mild β agonist effects and the resultant sympathomimetic effect is reflected as an increased heart rate, decreased systemic vascular resistance, and overall unchanged cardiac output in human patients [30]. However, this theory has not been supported by animal data [31]. Neither isoflurane nor sevoflurane overly sensitizes the myocardium to circulating catecholamines, thus they are unlikely to cause cardiac dysrhythmias in susceptible patients [30].


Hypoventilation and increased PaCO2 are often observed during inhalation anesthesia as a result of medullary respiratory center depression and reduced chest wall expansion due to anesthetic‐induced intercostal muscle relaxation [4]. Furthermore, positioning of ruminant patients in lateral or dorsal recumbency for surgery results in compression of the diaphragm, which collapses the caudal lung lobes by the cranial shifting of the rumen and further debilitates the ventilation function of an anesthetized ruminant patient [32, 33]. Sevoflurane produces a dose‐dependent increase in respiratory rate in human volunteers. Isoflurane increases the respiratory rate up to a concentration of 1 MAC. A further increase in isoflurane concentration is not associated with a further increase in the respiratory rate. Awake patients may be able to compensate for a decrease in respiratory rate by increasing the tidal volume to maintain normal minute ventilation and prevent the increase in PaCO2. However, dose‐dependent depression of the response of the medullary respiratory center to the increased PaCO2 is often observed, which prohibits central compensatory mechanism by increasing respiratory rate or tidal volume in an effort to maintain normal PaCO2 during isoflurane or sevoflurane anesthesia [23, 34]. Isoflurane and sevoflurane both produce bronchodilation in patients suffering from chronic obstructive pulmonary disease. Isoflurane vapor has a special pungent odor and has been shown to cause airway irritation, coughing, and breath holding during induction. On the contrary, sevoflurane has been described as “pleasant smelling,” and does not irritate the airway. Therefore, sevoflurane is often preferred for mask inductions [35].


Isoflurane, sevoflurane, and desflurane have little effect in overall hepatic and renal function in healthy patients. Isoflurane has been reported to decrease portal venous blood flow at 1.5 MAC, but total hepatic blood flow and hepatic arterial blood flow are shown to be within normal range. Therefore, hepatic perfusion is well maintained, which when combined with isoflurane‐induced vasodilation ensures adequate hepatic O2 delivery [36]. Of the three most popular inhalation anesthetics, isoflurane is probably the one that better maintains hepatic O2 supply and is least likely to cause hepatic injury. Nevertheless, sevoflurane and desflurane produce hepatic effects similar to isoflurane [37–39]. The elimination of these inhalation anesthetics depends primarily on ventilation rather than the hepatic metabolism. Sevoflurane has a higher hepatic metabolism (3%) than isoflurane (0.2%) and desflurane (0.02%). Apparently, sevoflurane is 10 times more vulnerable than isoflurane and 100 times more than desflurane to hepatic metabolism and the subsequent production of inorganic and organic fluoride [23]. Fluoride‐induced renal toxicity and renal dysfunction with a fluoride concentration of 50 μmol/l or greater have been previously documented with the administration of one of the older‐generation inhalation anesthetics, methoxyflurane [40]. Clinical studies in humans showed that plasma fluoride concentrations can be maintained below 80 μmol/l, even though peak plasma fluoride concentration is rarely reached due to methoxyflurane’s high blood solubility and slow rise in blood concentration [41]. Further evidence shows that renal dysfunction rarely occurs even with a peak plasma fluoride concentration of greater than 50 μmol/l, but less than 80 μmol/l, in the presence of high sevoflurane concentration and prolonged duration of anesthesia [41–46]. That being said, sevoflurane‐induced cardiovascular depression may enhance the renal toxicity effect by detrimental hepatic or renal effects, for example hepatocellular injury due to reduced hepatic blood flow and decreased O2 delivery and diminished renal function as a result of the decreased renal blood flow and glomerular filtration rate. Therefore, it is important to maintain normal cardiovascular function and ensure adequate hepatic and renal perfusion in anesthetized patients.


Compound A is a vinyl ether produced as one of the degradation products of sevoflurane presented in the CO2‐absorbent canister as a trace contaminant. Breakdown of sevoflurane to compound A has been associated with administration of high sevoflurane concentrations, the presence of the dry alkaline CO2 absorbent (e.g. soda lime or baralyme), the use of the low O2 flow in the breathing circuit, and the production of high temperature from the chemical interaction of exhaled CO2 with the CO2 absorbent [47–56]. In rats, inhalation of high compound A concentrations has been shown to cause fatal renal injuries [56]. However, it is believed that compound A is less toxic in humans due to lower β‐lyase enzyme activity compared to rats [57]. When a fresh O2 flow rate of 2 l/min was used in rats during sevoflurane anesthesia, which provided much higher O2 than the minimum metabolic O2 requirement of the rats, a very low concentration of compound A in the breathing circuit of the anesthetic machine was analyzed, and renal toxicity to the rats was not reported [34]. Increased production of compound A has been associated with higher CO2 absorbent temperatures up to 46 °C. Also, studies have shown that CO2 absorbent that contained NaOH and/or KOH often resulted in higher compound A production. No compound A was produced when NaOH‐ and KOH‐free CO2 absorbent was used [55, 58]. In rats, the concentrations of compound A that are associated with renal toxicity and median lethal concentration following 1 hour of sevoflurane anesthesia are reported to be 100–300 ppm [59] and – ppm [60], respectively. In humans, peak compound A concentration of less than 40 ppm was reported even after prolonged duration of sevoflurane anesthesia [49, 61]. Similarly, a peak compound A concentration of 61 ppm was reported in dogs anesthetized with sevoflurane using a low flow (fresh O2 flow rate 3 ml/kg/min), closed circuit system for 1 hour [62]. Kandel et al. [60] reported that renal injury in rats only occurred in the presence of a compound A concentration of at least 200 ppm with a maximum of 1 hour of exposure time. Fortunately, there is no report of compound A‐related renal toxicity under normal clinical conditions in humans or domestic animals.

Want more information on Digital x Ray Machine Veterinary? Feel free to contact us.